Filter Results By:

Products

Applications

Manufacturers

Showing results: 61 - 75 of 188 items found.

  • Surge/wave Simulators

    Suzhou 3ctest Electronic Co.,Ltd.

    Surge pulses occur due to direct or indirect lighting strokes to an external circuit. This leads to current or electromagnetic fields causing high voltage or current transients. Another source for surge pulsed is switching transients originating from switching disturbances and system faults.

  • High Voltage 50 Ω Pulse Generator

    TLP-8010A - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components

  • High Current SMU Family 2000 A

    AXC76xx - VX Instruments GmbH

    Generate very short, fully regulated current pulses from 2 ms to DC with up to 2000 A. Carry out measurements directly on the DUT with the integrated CMU and VMU.

  • Partial Discharge Detecting Detectors

    Hangzhou Xihu Electronic Institute

    Including pulse current PD detecto, high frequency PD detector, transient earth PD detector, ultra high frequency PD detector, and ultrasonic PD detector.

  • Floating 6-Ch Integrated Power Source

    PM0650 - Applied Test Resources

    The pulse channels provide voltage pulses with duration control 10us to 100ms, and measures current. The combination of capabilities provides a versatile solution on fulfilling the wide range of requirements on testing a device. The PM0650 may be floated up to ±1500V to facilitate HV isolation test of devices where outputs may be connected directly to line voltages.

  • Diode Laser Driver

    D200 - Highland Technology, Inc.

    The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.

  • Power Sources

    MS-Series - Pacific Power Source, Inc.

    The MS-Series Power Sources are high performance, high efficiency, AC to AC converters. Rugged powerful output provides up to 350 amps of pulse current for driving non-linear loads.

  • High Voltage 50 Ω Pulse Generator

    TLP-12010A - High Power Pulse Instruments GmbH

    - High pulse output current up to ±120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical 300 ps rise time- Wafer, package and system level TLP and HMM testing- 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 digital programmable pulse rise times out of: 300 ps to 50 ns (optional)- 1 built-in pulse width: 100 ns- Optional external pulse width extensions from 5 ns to 500 ns using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient software for system control and waveform data management- The software can control automatic probers for fast measurements of complete wafers- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface

  • High Voltage 50 Ω Pulse Generator

    TLP-8010C - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components

  • Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows

    ChenYang Technologies GmbH & Co. KG

    This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.

  • Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500

    DCS025 - Teledyne LeCroy

    The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.

  • Rebar Locator

    Profometer PM-600 - PASI srl

    Profometer PM-600 is an advanced cover meter for the precise and non destructive measurement of concrete cover and rebar diameters and the detection of rebar locations using the eddy current principle with pulse induction as the measuring method.

  • 120 A High Voltage 50 Ω Pulse Generator

    TLP-12010C - High Power Pulse Instruments GmbH

    - High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface

  • High Voltage Snubber Capacitor

    STP-01RN / STP-01RB - HK Film Capacitor Ltd

    This series of capacitors is Plastic Enclosure, Dry construction design and doesn't have leakage problem when compared with traditional Metal Enclosure Oil impregnated capacitors.Handle high surge current, RMS current and surge voltage with Temperature up to +105CCapacitance : 0.25uF - 60uF ( can be customized )Voltage range : 900Vdc to 5,300Vdc / 280Vrms to 1,600VrmsRMS Current - Irms : up to 80Armspeak to peak pulse current - Ipp : up to 15,000AppTemperature ranges : +85C / +105C

  • HBM Verification Tester

    HBM-VT - High Power Pulse Instruments GmbH

    - HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm

Get Help